Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement

Product Details
Customized Support: OEM, ODM, Obm
Brand Name: Atech
Measurement Range: Ozone 0-20mg/L(Ppm ) Temprature 0-60°c
Still deciding? Get samples of US$ 101.4/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
Years of Export Experience
The export experience of the supplier is more than 10 years
Multi-language Pioneer
2 languages freely used by foreign trade staff. include: English, Russian
Experienced Team
The supplier has 8 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (15)
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
  • Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
Find Similar Products
  • Overview
  • Product Description
  • Specification
  • Product Display
  • Company Profile
  • Exhibition
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
ADO-300
Power Supply
220VAC±10% 50/60Hz
Weight
0.9kg
Resolution
0.01mg/L,0.1°c
Accuracy
Pecede ±1%or ±0.01mg/L,±0.5
Cable Length
3m
Transport Package
Standard Carton Package
Specification
96*105*168mm
Trademark
Atech Sensor
Origin
Shaanxi, China

Packaging & Delivery

Package Size
11.00cm * 12.00cm * 18.00cm
Package Gross Weight
1.500kg

Product Description

Product Description

The advantage of the probe is that there is no need to add reagents, no need to replace the membrane head, maintenance is simple, and the service life is twice that of other electrodes. The probe uses a high-precision potential probe. Due to the requirement of high precision, we also send a free flow slot to make the measurement more acc.
 

Specification
Technical Parameters
Measuring range 
ozone 0-20.00 mg/L(ppm)
Resolution
0.01mg/L
Accuracy 
±1% or ±0.01 mg/L,
Control interface
Two groups of ON/OFF relay contact, divided into  high and low alarm control
Analog output
4~20mA or RS485
Relay
the relay lag value can be set freely. Relay load :3A 220VAC/24VDC.
Working conditions
environmental temperature of 0~60ºC, relative humidity ≤90%
Output load:<750Ω(4-20mA)
Working voltage: 220VAC10%,50/60Hz.
Dimension :96x105×168 mm
Hole size:92×92mm
Main Features
Protection Grade:IP65 (waterproof, dust-proof and damp-proof)
Digital LCD display and English operation menu .
The main components are imported  from foreign famous brand.
High accuracy  , high stability and strong anti-jamming.
Temperature compensation function: manual/automatic.
Watchdog:make sure the meter does not  go dead.
ABS plastic casing (waterproof, dust-proof and damp-proof).
Analog output: 4~20mA
Multi- parameters showed at the same time:Ozone value, temperature, output current, and alert of range ability etc.
Using advanced new-style constant voltage sensor. No need to change mebranes and reagents. It is easy to maintain, high sensitivity, high stability and quick response.
Product Display

Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality MeasurementResidual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality MeasurementResidual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality MeasurementResidual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement

Company Profile

Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality MeasurementResidual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement

Exhibition

Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality MeasurementResidual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement

Packaging & Shipping

Residual Chlorine Dissolved Ozone Analyzer for Potable Drinking Water Quality Measurement
FAQ

1.Q: How long is the delivery?

   -- Mostly within 10days

 2.Q:Can I get a sample? 

   --  Sure, contact our sales please

 3.Q:What is your MOQ? 

   --  1pcs

 4.Q: How about warranty time? 

   -- 12-18month

 5.Q: How can I visit your factory?

  -- Fly to Xian Yang air port, it's our pleasure to pick you up.

 6.Q:How do you control your quality ? 

    -- We have EPR system .we control from parts, process, testing, packing ,retesting.

        Every Sensor will be tested two times before reach you, after that sport test for the third time. Make sure about the quantity.