LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

Atech Sensor Co., Ltd
  • Audited Supplier
  • 5 yrs

Contact Supplier

Product Highlights

  • Ultrasonic Measurement Principle: Accurately measures heat energy released or absorbed by water flow in heat exchange systems.
  • Multiple Communication Protocols: Supports RS485, M-Bus, Pulse Output, and LoRaWAN for versatile data transmission.
  • IP68 Protection Class: Fully dust-tight and waterproof, ensuring durability in harsh environments.
  • Flexible Installation Options: Can be installed on inflow or return pipes with clear factory indication.
  • High Accuracy Class: Meets Class 2 accuracy standards for reliable heat energy measurement.
  • Comprehensive Certifications: Certified under Reach, CJ-T188-2018, EN1434, and CJ128-2007 standards.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan pictures & photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
  • LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
    LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

Find Similar Products

Product Description

 
Product Description

Ultrasonic heat meter

Ultrasonic heat meter is an instrument used to measure and display the heat energy released or absorbed by water flowing through the heat exchange system.When water flows through the Heat meter installed in the heat exchange system, calculate and display the heat energy released or absorbed by the system through a calculator according to the flow rate given by the flow sensor, the inlet and return water temperature signals given by the paired temperature sensor, and the time of water flow.
Detailed Photos
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan
LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan


LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/LorawanLCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/LorawanLCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan


 INSTALLATION REQUIREMENTS
1,Heat meter must be installed in dry accessible place. 2,Using professional installation tools to install the heat meter. 2,The heat meter both can be installed in Inflow pipe or Return flow pipe (factory default installed in the inflow pipe, if need to install on the return pipe, must be clearly indication before the factory during the production). When installation, should pay attention to the flow direction of medium is as the same as the arrow on the heat meter pipe body.Special note: no matter the heat meter installed on inflow pipe or return flow pipe, the temperature sensor should be properly connected ( red label for inflow pipe, blue label for return pipe).
4,When install the heat meter, front straight pipe length should not be less than 5 times of the pipe diameter, back straight pipe length should not be less than 2 times of the pipe diameter.
5,Pipe should be kept horizontal as much as possible, and pipeline's sectional area should be not big changes. 7,In order to ensure the meter accuracy, the cable of temperature sensor shall not be cut short or make longer. 7,When the meter is vertical installation in the same position in each floor, between each meter should have partition wall, prevent pipeline leaking or other things falling to damage the meter. 8,Heat meter horizontal installation as the best location, which is beneficial to the meter is normal working . 9,Suggest the meter installed in special box, and with lock, in order to avoid damage. 10,Replace the battery must by professional staff. 11,Wiring Guidelines: M-BUS wiring: black, white (non polarity)RS-485 wiring: red wire to VCC (24VDC+), blue wire to GND (24VDC -), brown wire to A, gray wire to B.
Product Parameters
                  Product parameters
R(Q3/Q1)
R100
 Accuracy Class
Class 2
Communication protocol
CJ-T188-2018,EN1434
Standard Compliance
CJ128-2007,EN1434
 Data interface
RS485,M-BUS
Temperature Range
4ºC~95ºC
 Power supply
Battery DC 3.6V lithium battery
 Protection Class
IP68
Max.permissible Working Pressure
1.6 MPa
Mechanical Structure
Integration
Working Environmental Requirement
Ambient temp.:-15ºC~ +70ºC;
Humidity:<100% (RH)
EMC Class
E1
Data Storage
24 Month
Static Consumpion
<12μA
Average working current
<25μA
 
 

LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

Company Profile

LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/LorawanLCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/LorawanLCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

Certifications

LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

Packaging & Shipping

LCD Display Ultrasonic Smart Heat Meter with M-Bus/RS-485/Pulse Output/Lorawan

About the Supplier

This supplier has been audited by SGS. Verify the report on the official SGS website with ID "QIP-ASR249228". Items marked "verified" are certified.

Watch Video
Watch Video
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd
Atech Sensor Co., Ltd

About Our Factory & Business Background

Address
Block B, Yangyang International, No. 132, Zhuque Street, Yanta Dist, Xi'an, Shaanxi, China

Our Production Capability & Technical Expertise

Main Products
Pressure Sensor, Pressure Transmitter, Level Measurement, Pressure Transducer, Water Level Sensor, Water Level Meter, Ultrasonic Level Sensor, Radar Level Sensor, Fuel Level Sensor, Flow Meter

FAQ

What communication protocols does the heat meter support?
It supports RS485, M-Bus, Pulse Output, and LoRaWAN.
Can the heat meter be installed on the return pipe?
Yes, it can be installed on the return pipe, but this must be clearly indicated before the factory during production.
What is the warranty period for this product?
The product comes with a 1-year warranty.
What are the installation requirements for the straight pipe lengths?
The front straight pipe length should be at least 5 times the pipe diameter, and the back straight pipe length should be at least 2 times the pipe diameter.
What is the protection class of the heat meter?
The heat meter has an IP68 protection class.
Who should replace the battery?
The battery must be replaced by professional staff.
What is the maximum permissible working pressure?
The maximum permissible working pressure is 1.6 MPa.